Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 230
Filtrar
1.
Appl Radiat Isot ; 205: 111173, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38211394

RESUMO

A 4πß(PPC)-γ coincidence system has been made at KRISS based on a digital DAQ. 60Co sources were measured to verify the system. The maximum detection efficiency for beta particles was estimated to be 96.7 %. Massic activities for sample sources had 0.005 % of the sample variability error, which was well within the expanded standard uncertainty of 0.54 % (k = 2).

2.
Interv Neuroradiol ; : 15910199221107440, 2022 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-35679068

RESUMO

Although accurate intracranial pressure (ICP) monitoring is essential for the diagnosis and treatment of severe brain diseases, current methods are performed invasively. Therefore, a safe and less invasive ICP measurement is required. The purpose of our study was to develop a simplified cranial cavity model for a better understanding of the relationship between the ICP and the pressure measurement within the dural venous sinus (DVS) to support the validity of using sinus pressure as the surrogate of the ICP. The in-house cranial cavity model had three components: the brain part, the DVS part, and the subarachnoid space (SAS) part. Pressure in other parts was measured when the pressure in the SAS part and, separately, brain part was increased from 0 (baseline) to 50 mmHg at intervals of 10 mmHg. When the pressure in the SAS part was increased from 10 to 50 mmHg at 10 mmHg interval, pressures of both the brain and DVS parts increased without significant difference (all P > 0.05). However, pressures in both the SAS and DVS parts differed while the pressure in the brain part was increased. The pressures in both parts showed about 70% of the increase in the brain part. Nevertheless, the pressures in the SAS and DVS parts were not significantly different (P > 0.05). A simplified in-house cranial cavity model was developed consisting of three compartments to represent the actual intracranial spaces. The pressure measurement within the DVS was feasible to use as a surrogate for the ICP measurement.

3.
Appl Radiat Isot ; 179: 110022, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34781075

RESUMO

The 129I standardization, using the movable 4πß(LS)-X(NaI(Tl)) coincidence system, was performed for two 129I radioactive sources - one was dissolved in 0.1M NaOH solution and the other in 0.1M HNO3 solution. The system incorporates three movable PM tubes for a ß-counter placed on a plane and a X-ray detector that can be moved up to the bottom of the vial. The ß-efficiency depending on the amount of radioactive solution was investigated with 14 liquid scintillation samples prepared by gravimetrically dispensing 4.4-145 mg of 129I radioactive solution. The ß-efficiencies above 90% were observed at less than 56 mg, but it was at most 70% at 145 mg. This occurred regardless of the activity of the sample or the type of chemical solution used to dissolve 129I source. The activity concentration of each 129I source was determined by efficiency-extrapolation method for samples with an activity range of 0.28-4.5 kBq. The ß-efficiency points were derived over 10 intervals by moving 3-PM tubes in fine steps of about 1 mm from the sample. The highest value for ß-efficiency was 95%. The combined uncertainty were 0.25% and 0.26%, respectively. The stated precision obtained using the system is better than that previously reported in the literature obtained by the triple to double coincidence ratio (TDCR) or the CIEMAT/NIST efficiency tracing method.

4.
Appl Radiat Isot ; 174: 109743, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33915348

RESUMO

A new movable 3PM-γ coincidence system, based on 4πß(LS)-γ coincidence counting, for activity measurement of ß-γ emitters has been designed at the Korea Research Institute of Standards and Science (KRISS). The system incorporates 3 PM tubes on the plane and two detectors placed above and below the center of the plane. The 3 PM tubes for ß-counters in the plane are movable up to 100 mm from a liquid scintillation vial, thus enabling the variation of ß-detection efficiencies by a geometrical technique. A NaI(Tl) γ-counter was set above for the present work. The ß-event is determined by counting the logical sum of three double coincidences. All the necessary electronics, i.e., logical sum, adjusting the duration of dead-time of each counting channel and coincidence resolving times, and analyzing coincidence relation, were specially designed to be fabricated in an integrated circuit. Details of the detectors, the electronics, the overall movable 3PM-γ coincidence system are presented, as well as the results of investigations to assess its operating characteristics. Validation measurements have been performed with 60Co and 57Co sources. The highest ß-detection efficiency achieved with 60Co and 57Co was 97% and 95%, respectively. The activity concentration determined with a new system agreed with calibrated values within the uncertainty range. Further results from validation measurements and the corresponding uncertainty budgets are presented.

5.
Osteoporos Int ; 31(12): 2373-2382, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32642852

RESUMO

Bone disorder is a common complication of chronic kidney disease (CKD). The clinical usefulness of bone mineral density (BMD) in CKD is not well known. Our study shows that low BMD is associated with physical activity and dietary Na/K intake ratio and can predict poor renal outcome in non-dialysis CKD. PURPOSE: Despite evidence of a link between bone mineral disorders and chronic kidney disease (CKD), the clinical implications of bone mineral density (BMD) in CKD are not well established. We investigated risk factors and renal outcomes of low BMD in CKD. METHODS: We analyzed data from the KNOW-CKD. BMD measured by dual-energy x-ray absorptiometry was classified by T score: normal (T score ≥ - 1.0), osteopenia (- 1.0 > T score > - 2.5), and osteoporosis (T score ≤ - 2.5) of the lumbar spine, hip, or femoral neck. Logistic regression analysis to assess risk factors of low BMD (T score < - 1.0) and Cox proportional hazards models to estimate risk of incident end-stage renal disease (ESRD). RESULTS: Low BMD was prevalent (osteopenia 33%; osteoporosis 8%) in 2128 adults with CKD (age 54 ± 12 years; male 61%). Over a median follow-up of 4.3 years, there were 521 cases of incident ESRD. Lower BMD was associated with female sex, older age, low eGFR, low BMI, and lifestyle factors of physical activity (odds ratio (OR) = 0.62, 95% confidence interval (0.49-0.77)) and spot urine Na/K ratio (1.07 (1.00-1.15)). In adjusted Cox models, low BMD was associated with increased incident ESRD (hazard ratio (HR) = 1.14 (0.92-1.41) for osteopenia; 1.43 (1.01-2.04) for osteoporosis, P for trend < 0.05) compared with the reference of normal BMD. The association between low BMD and ESRD was similar according to T score discordance classification. CONCLUSIONS: Low BMD was associated with modifiable lifestyle factors including low physical activity and high dietary Na/K intake ratio. The presence of low BMD is associated with poor renal outcomes in non-dialysis CKD.


Assuntos
Doenças Ósseas Metabólicas , Insuficiência Renal Crônica , Absorciometria de Fóton , Adulto , Idoso , Densidade Óssea , Doenças Ósseas Metabólicas/epidemiologia , Doenças Ósseas Metabólicas/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/complicações , Fatores de Risco
6.
Appl Radiat Isot ; 162: 109171, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32501226

RESUMO

We have developed an online digital signal processing system based on an FPGA. The system consists of pile-up rejection, baseline restorer, peak detection and pole-zero cancellation for evaluation of deposited energy in the detector. The shaping algorithm employed is a Moving Window Deconvolution (MWD) to shape digitized data into a trapezoidal form. For the purpose of verification, the developed digital system was tested for 137Cs gamma rays. The entire system is programmed using the LabVIEW environment.

7.
Appl Radiat Isot ; 164: 109228, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32554121

RESUMO

A radon calibration system is being developed with a high-sensitivity radon detector using electrostatic collection and an alpha spectrometer. Eight radon cells, each with a volume of 1.354 L, are integrated to achieve a high-sensitivity radon monitor with a total detector volume of 10.832 L. The sensitivity is estimated to be 35.6 ± 0.2 (36.8 ± 0.2) times higher relative to the RAD7 radon monitor for the detection of 218Po (214Po), respectively.


Assuntos
Radiometria/instrumentação , Radônio/análise , Calibragem , Limite de Detecção , Eletricidade Estática
8.
Appl Radiat Isot ; 164: 109238, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32554125

RESUMO

Korea Research Institute of Standards and Science (KRISS) is developing a length-compensated proportional counting (LCPC) system as a primary system for standardization of beta emitting radioactive gases. The pilot experiment was performed with 85Kr and the optimized high voltage and pressure were found to be 1700 V and 0.203 MPa, respectively. The total activity of 85Kr was deduced by the length compensation of each count. The expanded uncertainty was estimated to be around 0.8% (k = 2) for the 85Kr measurement.

9.
Eur J Neurol ; 27(2): 343-351, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31535427

RESUMO

BACKGROUND AND PURPOSE: The rate at which the chance of a good outcome of endovascular stroke therapy (EVT) decays with time when eligible patients are selected by baseline diffusion-weighted magnetic resonance imaging (DWI-MRI) and whether ischaemic core size affects this rate remain to be investigated. METHODS: This study analyses a prospective multicentre registry of stroke patients treated with EVT based on pretreatment DWI-MRI that was categorized into three groups: small [Diffusion-Weighted Imaging Alberta Stroke Program Early Computed Tomography Score (DWI-ASPECTS)] (8-10), moderate (5-7) and large (<5) cores. The main outcome was a good outcome at 90 days (modified Rankin Scale 0-2). The interaction between onset-to-groin puncture time (OTP) and DWI-ASPECTS categories regarding functional outcomes was investigated. RESULTS: Ultimately, 985 patients (age 69 ± 11 years; male 55%) were analysed. Potential interaction effects between the DWI-ASPECTS categories and OTP on a good outcome at 90 days were observed (Pinteraction  = 0.06). Every 60-min delay in OTP was associated with a 16% reduced likelihood of a good outcome at 90 days amongst patients with large cores, although no associations were observed amongst patients with small to moderate cores. Interestingly, the adjusted rates of a good outcome at 90 days steeply declined between 65 and 213 min of OTP and then remained smooth throughout 24 h of OTP (Pnonlinearity  = 0.15). CONCLUSIONS: Our study showed that the probability of a good outcome after EVT nonlinearly decreased, with a steeper decline at earlier OTP than at later OTP. Discrepant effects of OTP on functional outcomes by baseline DWI-ASPECTS categories were observed. Thus, different strategies for EVT based on time and ischaemic core size are warranted.


Assuntos
Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Alberta , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/terapia , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Tempo para o Tratamento , Resultado do Tratamento
11.
Bone Joint J ; 101-B(6): 695-701, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31154845

RESUMO

AIMS: The purpose of this study was to determine the functional outcome and implant survivorship of mobile-bearing total ankle arthroplasty (TAA) performed by a single surgeon. PATIENTS AND METHODS: We reviewed 205 consecutive patients (210 ankles) who had undergone mobile-bearing TAA (205 patients) for osteoarthritis of the ankle between January 2005 and December 2015. Their mean follow-up was 6.4 years (2.0 to 13.4). Functional outcome was assessed using the Ankle Osteoarthritis Scale, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, 36-Item Short-Form Health Survey (SF-36) score, visual analogue scale, and range of movement. Implant survivorship and complications were also evaluated. RESULTS: There were significant improvements in all functional outcome categories between the preoperative and final follow-up assessments (p < 0.001). Patients showed marked improvement in clinical outcomes in terms of pain, function, and quality of life. The overall implant survivorship was 91.7% at a mean follow-up of 6.4 years. In all, 33 major complications were identified with a 15.7% rate, resulting in 12 prosthesis failures (5.7%). Periprosthetic osteolysis (19 cases; 9.0%) was the most frequent complication. CONCLUSION: Mobile-bearing TAA resulted in improved functional outcomes, a low major complication rate, and excellent implant survivorship at a mean follow-up of 6.4 years. Cite this article: Bone Joint J 2019;101-B:695-701.


Assuntos
Artroplastia de Substituição do Tornozelo/métodos , Osteoartrite/cirurgia , Adulto , Idoso , Avaliação da Deficiência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Qualidade de Vida , Recuperação de Função Fisiológica , Taxa de Sobrevida , Resultado do Tratamento
12.
J Environ Radioact ; 184-185: 46-52, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29334620

RESUMO

Food samples are collected nationwide from January 2016 to February 2017 and their contents of artificial radionuclides are measured to address the growing concerns regarding the radioactive contamination of food products in Korea. Specifically, 900 food samples are collected for this study and their contents of representative artificial radionuclides 134Cs, 137Cs, 239,240Pu, and 90Sr are analyzed. The analysis shows that the activity concentrations of 137Cs in fish range from minimum detectable activity (MDA) to 340 mBq/kg of fresh weight. The concentration factor (CF) determined for 137Cs as a measure of its bioavailability is calculated to be ca. 74 and found to be very similar to that (100) recommended by the International Atomic Energy Agency. With an MDA of <0.221 mBq/kg, the results reveal that 239,240Pu values in fish are below the MDA. The activity concentrations of 137Cs and 90Sr are lower than the MDA in both shellfish and seaweed, while the activity concentrations of 239,240Pu in shellfish range from 0.26 to 2.18 mBq/kg, and for seaweed samples range from 2.07 to 3.38 mBq/kg. The atom ratios of 240Pu/239Pu in shellfish caught at the Korean coast vary from 0.209 to 0.237, with a mean of 0.227. The higher 240Pu/239Pu atom ratio determined in shellfish is thought to be caused by the plutonium transported from the Pacific Proving Grounds rather than other sources such as the Fukushima nuclear power plant accident. The activity concentrations of 137Cs in mushrooms are found to vary from 1.0 to 21.4 Bq/kg, with the highest concentrations observed in the Oak (shiitake) and Sarcodon asparatus. 134Cs is detected in three mushroom specimens collected from Jeju Island and about 3-3.6% of 137Cs present in the wild mushrooms native to the Jeju Island are introduced as a result of the Fukushima nuclear plant accident. The annual effective doses of 137Cs received through consumption of mushrooms and fish are 2.0 × 10-4 mSv yr-1 and 3.9 × 10-5 mSv yr-1, and those values are negligible compared to the annual effective doses limit of 1 mSv yr-1.


Assuntos
Contaminação Radioativa de Alimentos/análise , Contaminação Radioativa de Alimentos/estatística & dados numéricos , Acidente Nuclear de Fukushima , Monitoramento de Radiação , Poluentes Radioativos , Animais , Peixes , Plutônio/análise , República da Coreia , Alimentos Marinhos/análise
13.
Appl Radiat Isot ; 134: 51-55, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28673731

RESUMO

A method is presented for calculating the expected number of counts in peaks that have a large relative peak-area uncertainty and appear in measured gamma-ray spectra. The method was applied to calculations of the correction factors for peaks occurring in the spectra of radon daughters. It was shown that the factors used for correcting the calculated peak areas to their expected values decrease with an increasing relative peak-area uncertainty. The accuracy of taking the systematic influence inducing the correction factors into account is given by the dispersion of the correction factors corresponding to specific peaks. It was shown that the highest accuracy is obtained in the peak analyses with the GammaVision and Gamma-W software.

14.
Appl Radiat Isot ; 134: 177-181, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28982543

RESUMO

A 24 segmented HPGe coaxial detector was set up with a digitized data acquisition system (DAQ). The DAQ was composed of a digitizer (5 × 107sampling/s), a Field-Programmable Gate Array (FPGA), and a real time operating system. The Full Width Half Maximum (FWHM), rise time, signal characteristics, and spectra of a 137Cs source were evaluated. The data were processed using an in-house developed gamma-ray tracking system.

15.
Appl Radiat Isot ; 134: 385-390, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29248210

RESUMO

An international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the pilot laboratory, distributing aliquots of a 68Ge/68Ga solution. Results for the activity concentration, CA, of 68Ge at a reference date of 12h00 UTC 14 November 2014 were submitted by 17 laboratories, encompassing many variants of coincidence methods and liquid-scintillation counting methods. The first use of 4π(Cherenkov)ß-γ coincidence and anticoincidence methods in an international comparison is reported. One participant reported results by secondary methods only. Two results, both utilizing pure liquid-scintillation methods, were identified as outliers. Evaluation using the Power-Moderated Mean method results in a proposed Comparison Reference Value (CRV) of 621.7(11)kBqg-1, based on 14 results. The degrees of equivalence and their associated uncertainties are evaluated for each participant. Several participants submitted 3.6mL ampoules to the BIPM to link the comparison to the International Reference System (SIR) which may lead to the evaluation of a Key Comparison Reference Value and associated degrees of equivalence.

16.
Appl Radiat Isot ; 134: 363-365, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29173812

RESUMO

The Korea Research Institute of Standards and Science (KRISS) participated, in 2015, in an international Key Comparison (KC) of gaseous radon-222 activity named CCRI (II) -K2.Rn-222 to confirm international equivalence of KRISS-established gaseous radon-222 measurement standards. LNHB acted as KC pilot laboratory. This paper describes the KC measurement procedure followed at KRISS using the defined solid angle counting method together with auxiliary relative measurement methods and presents the results.

17.
Appl Radiat Isot ; 134: 257-262, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28709738

RESUMO

A comparison of calculations of the activity of a 3H2O liquid scintillation source using the same experimental data set collected at the LNE-LNHB with a triple-to-double coincidence ratio (TDCR) counter was completed. A total of 17 laboratories calculated the activity and standard uncertainty of the LS source using the files with experimental data provided by the LNE-LNHB. The results as well as relevant information on the computation techniques are presented and analysed in this paper. All results are compatible, even if there is a significant dispersion between the reported uncertainties. An output of this comparison is the estimation of the dispersion of TDCR measurement results when measurement conditions are well defined.

18.
Bone Joint J ; 99-B(10): 1335-1342, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28963155

RESUMO

AIMS: The purpose of this study was to compare the clinical and radiographic outcomes of total ankle arthroplasty (TAA) in patients with pre-operatively moderate and severe arthritic varus ankles to those achieved for patients with neutral ankles. PATIENTS AND METHODS: A total of 105 patients (105 ankles), matched for age, gender, body mass index, and follow-up duration, were divided into three groups by pre-operative coronal plane tibiotalar angle; neutral (< 5°), moderate (5° to 15°) and severe (> 15°) varus deformity. American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, a visual analogue scale (VAS), and Short Form (SF)-36 score were used to compare the clinical outcomes after a mean follow-up period of 51 months (24 to 147). RESULTS: The post-operative AOFAS, VAS scores, range of movement and complication rates did not significantly differ among three groups. However, there was less improvement in the SF-36 score of the severe varus group (p = 0.008). The mean post-operative tibiotalar alignment was 2.6° (0.1° to 8.9°), 3.1° (0.1° to 6.5°) and 4.6° (1.0° to 10.6°) in the neutral, moderate and severe groups respectively. Although the severe varus group showed less corrected alignment than the neutral group, the mean tibiotalar angles of the three groups were within neutral alignment. CONCLUSION: TAA for moderate and severe varus arthritic deformity showed similar satisfactory clinical and radiographic outcomes as those obtained by patients in the neutral group when post-operative neutral alignment was achieved. Cite this article: Bone Joint J 2017;99-B:1335-42.


Assuntos
Articulação do Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/métodos , Deformidades Articulares Adquiridas/cirurgia , Osteoartrite/cirurgia , Amplitude de Movimento Articular , Idoso , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/fisiopatologia , Feminino , Seguimentos , Humanos , Deformidades Articulares Adquiridas/diagnóstico , Deformidades Articulares Adquiridas/etiologia , Masculino , Pessoa de Meia-Idade , Osteoartrite/complicações , Osteoartrite/diagnóstico , Radiografia , Estudos Retrospectivos , Resultado do Tratamento
19.
Orthop Traumatol Surg Res ; 103(5): 691-695, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28559143

RESUMO

BACKGROUND: Skeletal traction is performed to temporarily stabilize fracture sites before surgery in patients with femoral fracture. To date, however, there is no study evaluating the difference in the degree of the recovery, of the muscle strength, as well as muscle atrophy following skeletal traction. The purpose of this study was to compare the degree of recovery of rectus femoris muscle strength after surgery in association with muscle atrophy by analyzing the duration of preoperative tibial traction, age and sex in patients with femoral fracture. HYPOTHESIS: Rectus femoris muscle atrophy will progress depending on the duration of preoperative tibial traction, age and sex in patients with femoral fracture. PATIENTS AND METHOD: Thirty-one patients who underwent preoperative pretibial skeletal traction and intramedullary nailing were divided into two groups according to the traction period: group A (n=12) with a duration of traction of <7 days (mean: 4.08±1.78 days) and group B (n=19) ≥7 days (mean: 13.63±7.17 days). The degree of muscle atrophy and recovery were compared between the two groups, according to age and gender. The degree of muscle atrophy was measured by the difference in thickness of the rectus femoris between pre- and post-traction using ultrasound. The degree of muscle recovery was evaluated by the Q-setting and heel off time. Clinical outcome was evaluated by the non-union rate and Lysholm score. RESULTS: The degree of muscle atrophy was 0.99±0.14mm in group A and 2.22±0.11mm in group B (P<0.001). The Q-setting time was 4.83±0.94 days in group A and 6.56±1.38 days in group B (P=0.001). Heel off time was also shorter in group A at 2.58±0.90 days, taking 3.72±1.27 days in group B (P=0.012). The recovery rate in the rectus femoris was significantly higher in group A than in group B (P<0.001). There was no significant difference in non-union rate between group A and B (P=0.672) but the mean Lysholm score at the last follow-up was significantly higher in group A than in group B (P=0.006). However, no significant differences were detected in the mean thickness of the rectus femoris, Q-setting, and heel off time between the different age and gender groups (P<0.05). CONCLUSIONS: The prolonged duration of preoperative skeletal traction indicates not only that the resulting disuse atrophy would progress further but also that the muscle atrophy would be accelerated more rapidly for shorter periods of time, based on a cut-off value of 7 days. In addition, the rate of rectus femoris muscle recovery and clinical outcomes were lower in patients undergoing traction for longer periods of time. This indicates that it would be effective for increasing the rate of the recovery and minimizing the occurrence of post surgical complications if surgeons could perform surgery at the earliest possible opportunity following traction, within seven days after the onset of trauma. LEVEL OF EVIDENCE: IV, retrospective cohort study.


Assuntos
Fraturas do Fêmur/terapia , Atrofia Muscular/etiologia , Músculo Quadríceps/patologia , Músculo Quadríceps/fisiopatologia , Tração/efeitos adversos , Adolescente , Adulto , Idoso , Diáfises/lesões , Feminino , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas , Humanos , Escore de Lysholm para Joelho , Masculino , Pessoa de Meia-Idade , Força Muscular , Atrofia Muscular/fisiopatologia , Período Pré-Operatório , Músculo Quadríceps/diagnóstico por imagem , Recuperação de Função Fisiológica , Estudos Retrospectivos , Tíbia , Fatores de Tempo , Tração/métodos , Ultrassonografia , Adulto Jovem
20.
Hong Kong Med J ; 23(3): 264-71, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28473651

RESUMO

INTRODUCTION: In setting up a disease registry for fragility fractures in Hong Kong, we conducted a retrospective systematic study on the management of fragility hip fractures. Patient outcomes were compared with the standards from our orthopaedic working group and those from the British Orthopaedic Association that runs a mature fracture registry in the United Kingdom. METHODS: Clinical data on fragility hip fracture patients admitted to six acute major hospitals in Hong Kong in 2012 were captured. These included demographics, pre- and post-operative assessments, discharge details, complications, and 1-year follow-up information. Analysis was performed according to the local standards with reference to those from the British Orthopaedic Association. RESULTS: Overall, 91.0% of patients received orthopaedic care within 4 hours of admission and 60.5% received surgery within 48 hours. Preoperative geri-orthopaedic co-management was received by 3.5% of patients and was one of the reasons for the delayed surgery in 22% of patients. Only 22.9% were discharged with medication that would promote bone health. Institutionalisation on discharge significantly increased by 16.2% (P<0.001). Only 35.1% of patients attended out-patient follow-up 1 year following fracture, and mobility had deteriorated in 69.9% compared with the premorbid state. Death occurred in 17.3% of patients within a year of surgery compared with 1.6% mortality rate in a Hong Kong age-matched population. CONCLUSIONS: The efficiency and quality of acute care for fragility hip fracture patients was documented. Regular geri-orthopaedic co-management can enhance acute care. Much effort is needed to improve functional recovery, prescription of bone health medications, attendance for follow-up, and to decrease institutionalisation. A Fracture Liaison Service is vital to improve long-term care and prevent secondary fractures.


Assuntos
Fraturas do Quadril/cirurgia , Procedimentos Ortopédicos/métodos , Qualidade da Assistência à Saúde , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Fraturas do Quadril/mortalidade , Fraturas do Quadril/patologia , Hong Kong , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...